SYSTEM_ALARM_CLEARED

Maps to the ietf-hardware YANG model.

Implemented for

  • junos

Syslog message example

<28>Jul  8 23:04:13  vmx01 alarmd[2449]: Alarm cleared: Pwr supply color=YELLOW, class=CHASSIS, reason=PEM 1 Fan Failed

Structured message example

{
  "error": "SYSTEM_ALARM_CLEARED",
  "facility": 3,
  "host": "vmx01",
  "ip": "127.0.0.1",
  "message_details": {
      "date": "Jul  8",
      "facility": 3,
      "host": "vmx01",
      "hostPrefix": null,
      "message": "Pwr supply color=YELLOW, class=CHASSIS, reason=PEM 1 Fan Failed",
      "pri": "28",
      "processId": "2449",
      "processName": "alarmd",
      "severity": 4,
      "tag": "Alarm cleared",
      "time": "23:04:13"
  },
  "os": "junos",
  "severity": 4,
  "timestamp": 1594249453,
  "yang_message": {
      "hardware-state": {
          "component": {
              "supply": {
                  "class": "CHASSIS",
                  "name": "supply",
                  "state": {
                      "alarm-reason": "PEM 1 Fan Failed",
                      "alarm-state": 4
                  }
              }
          }
      }
  },
  "yang_model": "ietf-hardware"
}