SYSTEM_ALARM_CLEARED¶
Maps to the ietf-hardware YANG model.
Implemented for¶
- junos
Syslog message example¶
<28>Jul 8 23:04:13 vmx01 alarmd[2449]: Alarm cleared: Pwr supply color=YELLOW, class=CHASSIS, reason=PEM 1 Fan Failed
Structured message example¶
{
"error": "SYSTEM_ALARM_CLEARED",
"facility": 3,
"host": "vmx01",
"ip": "127.0.0.1",
"message_details": {
"date": "Jul 8",
"facility": 3,
"host": "vmx01",
"hostPrefix": null,
"message": "Pwr supply color=YELLOW, class=CHASSIS, reason=PEM 1 Fan Failed",
"pri": "28",
"processId": "2449",
"processName": "alarmd",
"severity": 4,
"tag": "Alarm cleared",
"time": "23:04:13"
},
"os": "junos",
"severity": 4,
"timestamp": 1594249453,
"yang_message": {
"hardware-state": {
"component": {
"supply": {
"class": "CHASSIS",
"name": "supply",
"state": {
"alarm-reason": "PEM 1 Fan Failed",
"alarm-state": 4
}
}
}
}
},
"yang_model": "ietf-hardware"
}